Mini 220V 1.5KW Solar Pump Inverter Three Phase


General Parameters of 1.5kw solar pump inverter:


DC Input Range (VDC) 150 to 400
Recommended MPPT voltage 90-800Vdc
Max. MPTT efficiency >97%
Models SPIG300-1K5GB-2S-M
Max. applicable pump output power 1.5KW
Rated output voltage 220V/240V ac 3 phase
Output frequency range 0-50/60Hz
Rated output current 7A 
Dimension(W/H/D,mm) 143*86*114
Module IPM
weight 3.5kg
Max. efficiency >97%
Protective class I
Protection degree IP20
Environment temperature -25ºC-+70ºC 
Cooling method Natural cooling&fans
Display  LCD
Communication interface RS485
Altitude  3000m
Noise emission <50dB
compliance EMC&LVD

Features of 1.5kw solar pump converter:

Low carbon economy
In-built MPPT with high efficiency 
Pump specific protection
Remote monitoring
Best off grid solution
Perfect stable frequency output

Advantages of 1.5kw solar pump controller: 

1. High quality with 18 months warranty
2. Controlling with open-loop, closed-loop control
3. Install PID, main spindle control for water pump
4. Module bus communication protocol,RS485 communication
5. Simple PLC and multistage speed
6. In-built MPPT with high efficiency 
7. Speed tracking function 
8. Carrier frequency automatic adjustment;
9. Various protection mechanisms (over current/over voltage/overload, overheating, etc), to protect water pumps

Application:
 
1.Remote Villages, Homes, Cabins and Hunting Lodges (home use)
2.Irrigation for remote orchards, gardens, and greenhouses (irrigation water)
3.Wildlife watering at wild game parks and farms (irrigation water)
4.Fish pond water level maintenance and aeration (home use)
5.Swimming pool circulation& filtration pumps (home use)
6.Surface water pumping for landscaping streams and waterfalls (home use)
7.Cattle, Livestock watering systems (animal husbandry )
8.Water supply for sea island
9.Water treatment projects, for example, sea water desalination.

Installation diagram:




Electrical safety notice of 1.5kw solar pump driver!
 
Ignoring the following instructions can cause physical injury, or damage to the equipment.
Only qualified electricians are allowed to install and maintain the inverter!
• Never work on the photovoltaic generator or inverter and its input/output cables when the inverter is connected to the power system or to the photovoltaic generator.
• Before working inside the inverter cabinet, switch off or isolate the auxiliary voltage supply to the inverter.
• Isolate the inverter from the photovoltaic generator using the safety switch of the generator or by using the isolation switch.
• Do not touch the input of the isolation switch that has high DC voltage.
• After disconnecting the inverter from the power system or the DC input supply, wait for at least 5 minutes to discharge the intermediate circuit capacitors.
• Measure with a multimeter to ensure that no voltage is present.
• Impedance should be at least 1 MΩ.
• Voltage should be close to 0 V between inverter phases L1, L2, L3 and frame, and between module terminals Brk+ and Brk-.
• Do not make any insulation or voltage withstand tests on the inverter or on the inverter modules.
Note:
• The DC connection terminals Brk+ and Brk- carry a dangerous DC voltage of up to 800 V.
• Depending on the external and internal wiring, dangerous voltages of 115 V to 230 V may be present at the different terminals in the auxiliary circuit.
• At the inverter input, the photovoltaic cells generate DC voltage even at low intensity of sunlight.